Visara FEP-4600 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria komputerowe Visara FEP-4600. Visara FEP-4600 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - P/N 707118-001

FEP-4600 Users Guide and Maintenance Manual P/N 707118-001

Strona 2 - 2 707118-001

Chapter 1. Safety Information and Spec 1-2 707118-001 plug and must be plugged into grounded outlets. • Motherboard Battery: CAUTION - Make sure

Strona 3 - Revision Information

FEP-4600 Users Guide and Maintenance Manual 707118-001 1-3 • Handle a board by its edges only; do not touch its components, peripheral chips, memo

Strona 4

Chapter 1. Safety Information and Spec 1-4 707118-001 on the chassis and there are no loose parts/screws inside the chassis. 2. Make sure that a

Strona 5 - Table of Contents

FEP-4600 Users Guide and Maintenance Manual 707118-001 1-5 Product Compliance Information The server chassis is compliant with the following safety

Strona 6

Chapter 1. Safety Information and Spec 1-6 707118-001 Packing List and the Server Specifications The Accessory Box and the Rail Packaging Contents

Strona 7

FEP-4600 Users Guide and Maintenance Manual 707118-001 1-7 Meeting environmental requirements The following table lists the environmental requireme

Strona 8

Chapter 1. Safety Information and Spec 1-8 707118-001 Specifications General Specifications • 3.0+Ghz Intel Xeon™ Processor with EM64T and 1MB L

Strona 9 - Specifications

FEP-4600 Users Guide and Maintenance Manual 707118-001 1-9 Electrical interference and atmospheric considerations Electrostatic discharge in the vi

Strona 11

FEP-4600 Users Guide and Maintenance Manual 707118-001 2-1 Chapter 2. Chassis Description Chassis Front View and the Front Control Panel Chassis

Strona 13

Chapter 2. Chassis Description 2-2 707118-001 LED Button Descriptions

Strona 14 - 1-6 707118-001

FEP-4600 Users Guide and Maintenance Manual 707118-001 2-3 Chassis Rear View and the Back Panel

Strona 15

Chapter 2. Chassis Description 2-4 707118-001 Power Module LED Descriptions

Strona 16 - Specifications

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-1 Chapter 3. Administrative Interface Powering on the FEP-4600 The FEP-4600 is powered u

Strona 17

Chapter 3. Administrative Interface 3-2 707118-001 Select the ‘Administrative Functions’ button to get a login prompt. Depending on your browse

Strona 18

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-3 Type your password. There are three levels of user supported by the FEP-4600. • Admini

Strona 19

Chapter 3. Administrative Interface 3-4 707118-001 User Level Options There are three levels of users supported by the FEP-4600. This provides fo

Strona 20 - 2-2 707118-001

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-5 Viewing the FEP-4600 Status The Status panel can be viewed as the combination of three

Strona 21 - 707118-001 2-3

Chapter 3. Administrative Interface 3-6 707118-001 Note that by clicking on one of the SDLC interface buttons, the SDLC board is highlighted

Strona 22 - 2-4 707118-001

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-7 Varying Drop Status When a line is up, and you view the status of the drops on the line

Strona 23

FEP-4600 Users Guide and Maintenance Manual 707118-001 iii Revision Information Issue/Revision Schedule Comments Revision Number Date Initial Rele

Strona 24

Chapter 3. Administrative Interface 3-8 707118-001 Viewing the Hardware Monitor The Hardware panel displays the current status of the fans, tem

Strona 25

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-9 Maintenance Menu Options You can bring up the Maintenance Menu by selecting the ‘Mainte

Strona 26

Chapter 3. Administrative Interface 3-10 707118-001 Event Log You can view the Event Log by selecting it from the Maintenance menu. The resul

Strona 27

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-11 You can retrieve (capture) this log using your browser and the following procedure.

Strona 28

Chapter 3. Administrative Interface 3-12 707118-001 Creating a Recovery CD From the ‘Maintenance’ menu select the Recovery CD option. This ut

Strona 29

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-13 Updating the FEP-4600 Software FEP-4600 software can be easily updated using a variet

Strona 30

Chapter 3. Administrative Interface 3-14 707118-001 Update Software from Visara FTP Site You can update the FEP-4600 software from the Visara FT

Strona 31

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-15 When you press the [Install] button, the download and install process will begin. When

Strona 32

Chapter 3. Administrative Interface 3-16 707118-001 Update Software from an FTP Server This method makes use of a local FTP Server. To use this

Strona 33

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-17 To initiate the software update from the FTP server, press the ‘From FTP’ button. The f

Strona 34

iv 707118-001

Strona 35

Chapter 3. Administrative Interface 3-18 707118-001 Update from a CD To update FEP-4600 code from a CD, you must first get the new code onto a C

Strona 36

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-19 Update from a USB Port The FEP-4600 has multiple USB ports available. To upgrade throu

Strona 37

Chapter 3. Administrative Interface 3-20 707118-001 Select the update that you wish to upgrade to (usually the latest), then press the [Install

Strona 38

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-21 Restore Points Restore Points allow you to back up the FEP-4600 server code and config

Strona 39

Chapter 3. Administrative Interface 3-22 707118-001 The following ‘Manage Restore Points’ panel should appear. When the Restore Point has suc

Strona 40

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-23 Restoring a Restore Point From the ‘Manage Restore Points’ panel, select the [Restore]

Strona 41

Chapter 3. Administrative Interface 3-24 707118-001 Restarting the Server Initiating a restart of the server will result in the following action

Strona 42

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-25 The resulting panel should appear: Press the ‘Yes’ button to initiate the Restart p

Strona 43

Chapter 3. Administrative Interface 3-26 707118-001 Rebooting the FEP-4600 The ‘Reboot’ function of the FEP-4600 causes the platform to perfor

Strona 44

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-27 If you click the No button, a message is displayed: You may exit the panel by selec

Strona 45

FEP-4600 Users Guide and Maintenance Manual 707118-001 v Table of Contents Revision Information ...

Strona 46

Chapter 3. Administrative Interface 3-28 707118-001 Hard Drive Status The FEP-4600 uses RAID 1 mirroring of the drives (data written to one driv

Strona 47

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-29 Valid states can be: • OK • FAULTY • FAULTY REMOVED • OFFLINE If a partition is in

Strona 48

Chapter 3. Administrative Interface 3-30 707118-001 The FEP-4600 must boot from the C drive. If the C drive goes bad and the unit cannot boot, t

Strona 49

FEP-4600 Users Guide and Maintenance Manual 707118-001 3-31 Logout from the Administrative Interface To Logout, select the ‘Logout’ button locate

Strona 51

FEP-4600 Users Guide and Maintenance Manual 707118-001 4-1 Chapter 4. System Commands In addition to managing resources directly from the FEP-4600

Strona 52

Chapter 4. System Commands 4-2 707118-001 Inactivating an ESCON PATH: You can vary an ESCON path inactive by issuing this command. ‘yyyy’ represe

Strona 53

FEP-4600 Users Guide and Maintenance Manual 707118-001 4-3 Device Status This command allows you to display the status of the IODEVICE. ‘yyyy’ repr

Strona 54

Chapter 4. System Commands 4-4 707118-001 Operations in the zVM, VM/ESA Environment Device Status The query command allows you to display the st

Strona 55 - Chapter 4. System Commands

FEP-4600 Users Guide and Maintenance Manual 707118-001 4-5 Operations in the VTAM Environment PU4 links through the FEP-4600 appears to the system

Strona 56

vi 707118-001 Chapter 3. Administrative Interface... 3-1 Poweri

Strona 57

Chapter 4. System Commands 4-6 707118-001 Displaying Explicit Route Status: You can verify that an explicit route has been established through th

Strona 58

FEP-4600 Users Guide and Maintenance Manual 707118-001 4-7 PU 2.0 System Operations Activating a PU: This varies a PU active. All subservient LU

Strona 60

FEP-4600 Users Guide and Maintenance Manual 707118-001 5-1 Chapter 5. Field Replaceable Units Below are listed the parts that may be serviced on t

Strona 62

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-1 Chapter 6. Maintenance Important Safety Guidelines Caution: This product shall only

Strona 63

Chapter 6. Maintenance 6-2 707118-001 these screws or fasteners for easy identification.) 3. Press the release tabs to release the cover from i

Strona 64

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-3 Replacing the Motherboard Warning: Be sure to disconnect the power supply before openi

Strona 65 - Chapter 6. Maintenance

Chapter 6. Maintenance 6-4 707118-001 10. Remove the 11 Type A (6-32) screws fastening the motherboard to the chassis. 11. With the disconnected

Strona 66 - 6-2 707118-001

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-5 slots with the rear card opening on the chassis. 7. Raise the lever on CPU 1 socket. 8.

Strona 67 - Replacing the Motherboard

FEP-4600 Users Guide and Maintenance Manual 707118-001 vii Replacement Procedure ...

Strona 68 - Replacement Procedure

Chapter 6. Maintenance 6-6 707118-001 Removing/Installing ESCON, QSA, QSI, QBA and Token Ring PCBs Warning: Be sure to disconnect the power sup

Strona 69 - 707118-001 6-5

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-7 Hard Drive(s) Note: The hard drive(s) may be removed and replaced without first removin

Strona 70 - Token Ring PCBs

Chapter 6. Maintenance 6-8 707118-001 2. Pull the drive tray door upward and then pull the SCA drive tray out from the chassis. 3. Mount a h

Strona 71 - Hard Drive(s)

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-9 Replacing the Power Supply Note: The 760W power supply is an N+1 redundant power supply

Strona 72 - 6-8 707118-001

Chapter 6. Maintenance 6-10 707118-001 Warning: Do not open the casing of a power supply. Power supplies can only be accessed and serviced by a

Strona 73 - Replacing the Power Supply

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-11 CD-R/W Drive Removing/Installing CD-R/W Drive The CD-R/W drive is located in the upper

Strona 74 - 6-10 707118-001

Chapter 6. Maintenance 6-12 707118-001 Floppy Drive Removal/Installation This component is not hot-swappable, meaning system power must be turned

Strona 75 - CD-R/W Drive

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-13 System Fan Failure The fans run at 4300 rpm. If a fan fails, the ambient air temperatur

Strona 76 - 6-12 707118-001

Chapter 6. Maintenance 6-14 707118-001 Installing a new fan: (2 each 8 cm. Fans) Replace the failed fan with an identical 8-cm, 12 volt fan (Visa

Strona 77 - System Fan Failure

FEP-4600 Users Guide and Maintenance Manual 707118-001 6-15 Cable Connection Reference Chart In the event that a cable should happen to be removed

Strona 78 - 6-14 707118-001

viii 707118-001 Introduction The Visara FEP-4600 platform allows the migration from 37x5 Front End Processors of several features. The tools tradi

Strona 79

FEP-4600 Users Guide and Maintenance Manual 707118-001 1-1 Chapter 1. Safety Information and Technical Specifications Electrical Safety Guideli

Komentarze do niniejszej Instrukcji

Brak uwag