Visara eTerm 350 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria komputerowe Visara eTerm 350. Visara eTerm 350 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 70
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
eTerm 350 Windows-based Terminal
User’s Manual
P/N 707018-006
Przeglądanie stron 0
1 2 3 4 5 6 ... 69 70

Podsumowanie treści

Strona 1 - User’s Manual

eTerm 350 Windows-based TerminalUser’s ManualP/N 707018-006

Strona 2 - Electro-Magnetic Interference

1-4 707018-006eTerm 350 Windows-based TerminalInstallationConnecting the TerminalFollow these instructions to connect the terminal to its peripheral d

Strona 3 - Software License Agreement

707018-006 1-5Chapter 1. eTerm InstallationAppendicesTroubleshootingIf you are experiencing trouble with the terminal, refer to the following. If the

Strona 4

1-6 707018-006eTerm 350 Windows-based TerminalSpecificationsProcessor - Cyrix MediaGX™, 200MHzMain Memory - 32MB SDRAM (up to 128MB)Flash Memory - M-S

Strona 5 - Table of Contents

707018-006 2-1Chapter 2. eTerm Setup WizardConfiguring the UnitThe first time you power up the system, the Setup Wizard will lead you though theconfi

Strona 6

2-2 707018-006eTerm 350 Windows-based TerminalEnable/Disable Dynamic Assignment of IP AddressNetwork attached devices must contain a unique network id

Strona 7 - Usage Notice

707018-006 2-3Chapter 2. eTerm Setup WizardSpecify a Static IP AddressIf the method you selected on the prior screen was to enter a static IP Address

Strona 8 - Introduction

2-4 707018-006eTerm 350 Windows-based TerminalEnable/Disable Name Resolution ServicesThe screen shown below will only appear if you choose the Static

Strona 9 - Product Overview

707018-006 2-5Chapter 2. eTerm Setup WizardChoose Display ResolutionThe following screen lets you choose a display resolution.Select the desktop area

Strona 10 - Installation

2-6 707018-006eTerm 350 Windows-based TerminalConfigure Web AccessThe following screen lets you configure the local Internet Explorer browser.• Home P

Strona 11 - Appendices

707018-006 2-7Chapter 2. eTerm Setup WizardLocal Printer SetupThe following screen enables the setup of a local-attached printer to the eTerm 350. If

Strona 12 - Specifications

ii 707018-006The information contained in this document is subject to change without notice. Visara, Inc. makes no warranty of anykind with regard to

Strona 13 - Configuring the Unit

2-8 707018-006eTerm 350 Windows-based TerminalPrinter Model SetupThe following screen requires selecting of the printer’s Manufacturer then select the

Strona 14 - 2-2 707018-006

707018-006 2-9Chapter 2. eTerm Setup WizardPrinter DefaultThe following screen enables the local-attached printer to be the default printer whenrunni

Strona 15 - Specify a Static IP Address

2-10 707018-006eTerm 350 Windows-based TerminalFinishing the Setup WizardThis is the last screen of the Setup Wizard.• To review or change settings ma

Strona 16 - 2-4 707018-006

707018-006 3-1Chapter 3. eTerm TerminalConnectionTerminal Connection ManagerThe Terminal Connection Manager is used for helping you to manage your te

Strona 17 - Safe Boot

3-2 707018-006eTerm 350 Windows-based TerminalCreating a New ConnectionSelect the Configure tab; click the Add button to create a new connection.The f

Strona 18

707018-006 3-3Chapter 3. eTerm Terminal ConnectionSpecify Connection Name and ServerType a name for the new connection in Name field and the name of

Strona 19 - Printer Port Setup

3-4 707018-006eTerm 350 Windows-based TerminalAutomatic LogonIf you do not need an Automatic Logon to the server, click the Next button to continue.If

Strona 20 - Printer Name

707018-006 3-5Chapter 3. eTerm Terminal Connection• Domain:If the Terminal Servers in which you are creating the connection belongs to a WindowsNT do

Strona 21 - Additional Printer Setup

3-6 707018-006eTerm 350 Windows-based Terminal• Application file name:Select this option if you want an application to start automatically as soon as

Strona 22 - Restarting after Setup Wizard

707018-006 3-7Chapter 3. eTerm Terminal ConnectionConfiguring an Auto-start ConnectionYou can configure one or more connections to start automaticall

Strona 23 - Connection

707018-006 iiiSoftware License AgreementYou should carefully read the following terms and conditions before operating the eTerm 350. It containssoftwa

Strona 24 - Creating a New Connection

3-8 707018-006eTerm 350 Windows-based TerminalConnections Properties SheetConnection Name: When finishing either the Microsoft Remote Desktop Client (

Strona 25 - 707018-006 3-3

707018-006 3-9Chapter 3. eTerm Terminal ConnectionConfigure Properties Sheet• Add:This function is used for creating a new connection. Select the Con

Strona 26 - Automatic Logon

3-10 707018-006eTerm 350 Windows-based Terminal• Net Connections:Use this function to adjust the connection server name and the server address. If you

Strona 27 - 707018-006 3-5

707018-006 3-11Chapter 3. eTerm Terminal Connection• Startup:This function allows you choose the connection you want to startup. Select therequired c

Strona 28 - Deleting a Connection

3-12 707018-006eTerm 350 Windows-based TerminalCitrix ICA ClientIf you choose Citrix ICA Client, the Specify Connection Type dialog box will appear.Us

Strona 29 - Modifying a Connection

707018-006 3-13Chapter 3. eTerm Terminal ConnectionChoose the current server name appearing in the field. (You can also rename this server.)If desire

Strona 30 - Connections Properties Sheet

3-14 707018-006eTerm 350 Windows-based TerminalIf you want to automatically log on to the server, enter the information in User Name,Password, and Dom

Strona 31 - Configure Properties Sheet

707018-006 3-15Chapter 3. eTerm Terminal Connection• Use Printer Configuration Utility:Check this option if a printer is local-attached to the unit a

Strona 32 - 3-10 707018-006

3-16 707018-006eTerm 350 Windows-based Terminal• Configuring the ICA Client to Use a SOCKS ProxyIf you are using a SOCKS proxy server to limit access

Strona 33 - Hot-keys Functions

707018-006 3-17Chapter 3. eTerm Terminal ConnectionDial-Up ClientThe Dial-Up Client wizard configures the eTerm350 for a connection to a local orremo

Strona 35 - 707018-006 3-13

3-18 707018-006eTerm 350 Windows-based Terminal• Click the Next button. On the next dialog box, select the serial Com port that themodem is connected

Strona 36 - 3-14 707018-006

707018-006 3-19Chapter 3. eTerm Terminal Connection• Click the Next button. On the next dialog box, enter Username, Password andDomain (if required).

Strona 37 - 707018-006 3-15

3-20 707018-006eTerm 350 Windows-based Terminal• Click on the Finish button. The Terminal Connections Manager will now display atelephone icon (if dia

Strona 38 - 3-16 707018-006

707018-006 4-1Chapter 4. eTerm TerminalPropertiesTerminal PropertiesUnder a normal operation, you can press the [F2] key to reset the terminal proper

Strona 39 - Dial-Up Client

4-2 707018-006eTerm 350 Windows-based TerminalThrough the Terminal Properties property sheet, you can perform the followingconfiguration tasks:• Check

Strona 40 - 3-18 707018-006

707018-006 4-3Chapter 4. eTerm Terminal Properties• Answer Ye s to the following dialog box stating that you are required to restart theunit after t

Strona 41 - 707018-006 3-19

4-4 707018-006eTerm 350 Windows-based TerminalKeyboardFrom the Locale list box, select the desired Keyboard type. You will need to restartthe unit.Use

Strona 42 - 3-20 707018-006

707018-006 4-5Chapter 4. eTerm Terminal PropertiesDesktop Area and Refresh Frequency• Select the resolution and frequency of your monitor. 640x480 @6

Strona 43 - Properties

4-6 707018-006eTerm 350 Windows-based TerminalManually Assigning a Static IP Address• Press [F2] to display the Terminal Properties property sheet.• S

Strona 44 - Resetting Factory Defaults

707018-006 4-7Chapter 4. eTerm Terminal PropertiesReconfiguring Name ResolutionTo change whether and how hostnames used in connections are resolved t

Strona 45 - Input Tab

Page707018-006 vTable of ContentsChapter 1. eTerm Installation ... 1-1

Strona 46 - Display Tab

4-8 707018-006eTerm 350 Windows-based TerminalAudio TabTo adjust the volume and sound of the terminal, complete the following steps:• Press [F2] to di

Strona 47

707018-006 4-9Chapter 4. eTerm Terminal PropertiesSerial TabDial Up• Serial Port: Choose from the following Connection Types:• Hayes Compatible on CO

Strona 48 - Configure Terminal Name

4-10 707018-006eTerm 350 Windows-based Terminal• Connections Preferences• Baud Rate – Select the desired baud rate.• Data Bits – Select the desired Da

Strona 49 - Enable WINS

707018-006 4-11Chapter 4. eTerm Terminal PropertiesSecurity Tab• Terminal Properties Password Checkbox – Selecting this checkbox will allowthe user t

Strona 50 - Sounds Properties

4-12 707018-006eTerm 350 Windows-based Terminal• Server – Enter the FTP server IP address• File – Enter the path and filename of the upgrade image fil

Strona 51 - Port Settings Tab

707018-006 4-13Chapter 4. eTerm Terminal PropertiesAdvanced TabSetting• Load Terminal Default Settings (Retain Connection Manager Sessions) –Selecti

Strona 52 - Printers Tab

4-14 707018-006eTerm 350 Windows-based TerminalICA• Global ICA Client Settings Button – Displays the Global ICA Client Settings Window.The Global ICA

Strona 53 - Upgrade Tab

707018-006 4-15Chapter 4. eTerm Terminal Properties• Server Location Tab• Server Location – Server location (also called the ICA Browser or serverbro

Strona 54 - Upgrade/Local Time Setting

4-16 707018-006eTerm 350 Windows-based Terminal• Firewall Settings Tab• Use alternate address through firewall – Select this option to instruct the IC

Strona 55 - Advanced Tab

707018-006 4-17Chapter 4. eTerm Terminal PropertiesManagement• Enable SNMP Agent Checkbox – Selecting this checkbox will enable the SNMPagent to send

Strona 56 - 4-14 707018-006

vi 707018-006eTerm 350 Windows-based TerminalPageChapter 4. eTerm Terminal Properties ...

Strona 57 - 707018-006 4-15

4-18 707018-006eTerm 350 Windows-based TerminalNIC Mode Setting• Mode – Select the desired NIC speed based on your network configuration.Consult your

Strona 58 - Node Name

707018-006 4-19Chapter 4. eTerm Terminal PropertiesWeb TabIf applicable, the Web tab enables configuration of the local IE4.0 browser. Settingsthat c

Strona 60 - NIC Mode Setting

707018-006 5-1Chapter 5. eTerm 350 PlusConnection TypesHostConnect is the application which provides simultaneous connections to a varietyof host sys

Strona 61 - 707018-006 4-19

5-2 707018-006eTerm 350 Windows-Based TerminalConfiguring Host ConnectionsNew ConnectionCreate a new HostConnect connection by clicking the add button

Strona 62

707018-006 5-3Chapter 5. eTerm 350 PlusHost Name / AddressThe eTerm 350 supports Domain Name Services (DNS) names to make connectionswith network s

Strona 63 - Chapter 5. eTerm 350 Plus

5-4 707018-006eTerm 350 Windows-Based Terminal• 3270 TerminalsHostConnect supports emulation of a variety of 3270 terminal models and includessupport

Strona 64 - Configuring Host Connections

707018-006 5-5Chapter 5. eTerm 350 PlusAdditional Connection CapabilitiesDisplay Parameters, TN5250EThe 5250E Display Parameter screen allows entry

Strona 65 - Chapter 5. eTerm 350 Plus

5-6 707018-006eTerm 350 Windows-Based TerminalPrinter Parameters, TN5250EWhen TN5250E and terminal type 3812 are selected on the Connection Parameters

Strona 66 - 5-4 707018-006

707018-006 5-7Chapter 5. eTerm 350 PlusDisplay Parameters, TN3270Attention Key Action and System Request Key Action. You can override the defaultac

Strona 67

707018-006 1-1Chapter 1. eTerm InstallationUsage NoticeWarning- To reduce the risk of fire or electric shock, do not expose this productto rain or mo

Strona 68 - Printer Parameters, TN5250E

5-8 707018-006eTerm 350 Windows-Based TerminalPrinter Parameters, TN3270EWhen TN3270E and terminal type 3287 are selected on the Connection Parameters

Strona 69

1-2 707018-006eTerm 350 Windows-based TerminalIntroductionAbout the ProductThis Windows-based Terminal is a simple device that allows you to use Micro

Strona 70 - Printer Parameters, TN3270E

707018-006 1-3Chapter 1. eTerm InstallationProduct OverviewAir Vent1. Power Connector2. RJ-45 Network Connector3. Parallel Port Connector4. Audio Out

Komentarze do niniejszej Instrukcji

Brak uwag